Free guide · for architects, consultants and buyers

The LED wall spec guide.

Everything that decides whether an LED wall looks good and lasts: pitch, brightness, refresh rate, IP rating, power, structure, the questions to ask suppliers, and tender wording you can copy.

1. Pixel pitch and viewing distance

Pixel pitch (P) is the distance between LED centres in millimetres. It sets sharpness, resolution and a large share of the cost.

PitchMinimum viewing distanceBest viewing distanceTypical use
P1.251.3 m2.5–4 mControl rooms, boardrooms
P1.5–P1.861.5–1.9 m3–5.5 mBoardrooms, broadcast
P2–P2.52–2.5 m4–7.5 mLobbies, showrooms, auditoriums
P3–P43–4 m6–12 mHalls, shop fronts, campuses
P5–P65–6 m10–18 mFacades, outdoor signs
P8–P108–10 m16 m+Hoardings, highways

Rule of thumb: minimum viewing distance in metres ≈ pitch in mm. Best viewing distance ≈ 2–3 × that.

2. Brightness

LocationRecommended brightness
Indoor rooms and lobbies600–1,000 nits (calibrated lower for close viewing)
Behind shop glass / semi-outdoor2,000–3,500 nits
Outdoor, direct sun4,500–6,500 nits

Outdoor screens should have an ambient light sensor with auto-dimming. Full brightness at night causes glare and shortens LED life.

3. Refresh rate and grey scale

  • Refresh rate: 1,920 Hz is the minimum for signage. Specify 3,840 Hz or higher where the screen will be filmed or live-streamed (events, churches, auditoriums), otherwise cameras show scan lines.
  • Grey scale: 14-bit or higher for smooth gradients at low brightness.
  • Contrast: black-face LEDs and masks give better contrast in bright rooms.

4. Ingress protection (IP rating)

IP65 means dust-tight (6) and protected against water jets (5). In South Indian monsoons and coastal air, specify:

  • IP65 front and rear for outdoor cabinets, not front only.
  • Sealed power supplies and receiving cards inside the cabinet.
  • Waterproof connectors, cable glands and drip loops at every entry.
  • Corrosion-resistant fixings (galvanised or stainless) within about 5 km of the sea.

5. Cabinets, service access and spares

  • Front service where the screen is flush to a wall; rear service needs about 600–800 mm of walkway behind.
  • Die-cast aluminium cabinets for indoor walls: flatter, lighter and better seams.
  • Ask for 2–3% spare modules from the same production batch, so replacements match in colour.
  • Ask for a calibration report or seam-adjustment method.

6. Power and electrical

  • Typical peak load: indoor about 450–600 W/m², outdoor about 700–900 W/m². Average is about a third of peak.
  • Use 3-phase supply above about 5 kW peak, balanced across phases.
  • Dedicated DB with MCB/RCCB, a surge protection device (SPD) and a separate earth pit for outdoor screens.
  • Power sequencer or timer to avoid inrush current tripping breakers at switch-on.

Use our power calculator →

7. Structure

  • Indoor die-cast cabinets weigh about 25–30 kg/m²; outdoor about 35–55 kg/m², plus the steel frame.
  • Outdoor structures must be designed for wind load to IS 875 (Part 3) for the site's basic wind speed.
  • Get a structural drawing showing sections, anchors and, for poles, the foundation.

Use our weight and wind calculator →

8. Control and content

  • Synchronous control (live from a PC or video processor) for events and live feeds; asynchronous (stored player, updated over Wi-Fi/4G) for signage.
  • Video processor with the right inputs (HDMI, DVI, SDI) and enough capacity for the wall's resolution.
  • Remote content management and scheduling for multi-site or outdoor screens.
  • Content designed at the exact pixel resolution of the wall.

9. Questions to ask every supplier

  1. What exact pitch, cabinet size and resolution are you quoting?
  2. What is the peak and calibrated brightness in nits?
  3. What is the refresh rate and grey-scale depth?
  4. Is the outdoor cabinet IP65 at front and rear?
  5. Front or rear service? How are modules replaced?
  6. How many spare modules are included, from the same batch?
  7. Who designs and certifies the structure?
  8. What is the warranty, and who services it locally, how fast?
  9. Is installation by your own team or a subcontractor?
  10. What controller, processor and software are included?

10. Sample specification (copy into your tender)

Supply, installation, testing and commissioning of an [indoor / outdoor] LED video wall of [W] m × [H] m active area. Pixel pitch: P[ ] mm, SMD [ ] LEDs, black face. Resolution: [ ] × [ ] pixels (minimum). Brightness: ≥ [ ] nits, with automatic brightness control via ambient light sensor (outdoor). Refresh rate: ≥ 3,840 Hz. Grey scale: ≥ 14-bit. Cabinet: [die-cast aluminium / outdoor aluminium], [front / rear] serviceable, IP[65] front and rear (outdoor). Control: [synchronous / asynchronous] with video processor supporting [HDMI/DVI/SDI] inputs and remote content management. Power: peak ≤ [ ] W/m², average ≤ [ ] W/m²; dedicated DB with MCB, RCCB and SPD; separate earthing (outdoor). Structure: MS/GI frame designed for dead load and wind load to IS 875 (Part 3); structural drawing to be submitted for approval. Spares: minimum 3% modules and 1 power supply and receiving card per [ ] cabinets, from the same production batch. Warranty: [ ] years comprehensive on site, with response within [ ] hours. Training and content setup for client staff to be included.

Read the full guide free

Leave your name and number and the full guide opens straight away, including the copy-ready tender specification. We may follow up once on WhatsApp; no spam.

Loading the form…

Planning a display? Let's light it up.